Sanyo 36KHS72R 31,400 BTU Single Zone Wall-Mounted Heat Pump Ductless Split System with DC Inverter, Microprocessor Controls and Wireless Remote Control (KHS3672R Indoor/ CH3672R Outdoor)

Sanyo 36KHS72R 31,400 BTU Single Zone Wall-Mounted Heat Pump Ductless Split System with DC Inverter, Microprocessor Controls and Wireless Remote Control (KHS3672R Indoor/ CH3672R Outdoor) Reviews



More Picture


Sanyo 36KHS72R 31,400 BTU Single Zone Wall-Mounted Heat Pump Ductless Split System with DC Inverter, Microprocessor Controls and Wireless Remote Control (KHS3672R Indoor/ CH3672R Outdoor) Feature

  • The unit operates at maximum capacity by pressing a High Power Mode button.
  • The DC Inverter Air Conditioner affords continuous operation while it adjusts capacity according to
  • The accurate sensing of cooling or heating loads prevents frequent changes in capacity and ensures
  • The DC Inverter Air Conditioner uses a twin rotary compressor. Compared to the conventional single
Indoor Unit: KHS3672R. Outdoor Unit: CH3672R. Height: 14 9/16". Width: 59 1/16". Depth: 9 7/16". Net Weight: 72.8 lbs.. Height: 30 23/32". Width: 37". Depth: 13 3/8". Net Weight: 143.0 lbs.. Capacity - Cooling: 31,400 (9,500~31,400) BTU/h. Capacity - Heating: 36,400 (8,000~36,400) BTU/h. Moisture Removal - High: 10.0 Pints/H. Dry Air Flow - Hi/ Med/ Low: 830/ 710/ 590 CFM. SEER - Cooling: 15.9. HSPF - Heating: 9.0. COP - Heating: N/A. Power Supply: 230/208 Volts, 1 Phase, 60 Hz. Running Amps - Cooling: 17.9/19.8 Amps. Running Amps - Heating: 15.9/17.6 Amps. Power Input - Cooling: 3,750/3,750 Watts. Power Input - Heating: 3,320/3,320 Watts. Back-up Heater: N/A. Fuse or Circuit Breaker Capacity - Indoor Unit: 15 Amps. Fuse or Circuit Breaker Capacity - Outdoor Unit: 35 Amps. Controls: Microprocessor. Low Ambient Control: Built-in 0°F. Wireless Remote Controller: Included. Wired Remote Controller: RCS-TM80BG. Fan Speeds: 3 and Automatic Control/ Variable. Timer: N/A. Air Deflection - Horizontal: N/A. Air Deflection - Vertical: Automatic. Air Filter: Washable. Refrigerant: R-410A. Refrigerant Control: Electric Expansion Valve. Operation Sound - In (Hi/ Med/ Low): 48/ 44/ 40 dB-A. Operation Sound - Outdoor (Hi): 52 dB-A. Refrigerant Piping - Type: Flare Type. Refrigerant Piping - Discharge: 3/8" Discharge. Refrigerant Piping - Suction: 5/8" Suction. Refrigerant Pipe Length: Max. 165 ft.. Elevation Difference - Outdoor Above: Max. 100 ft. (This is the maximum elevation difference when the indoor unit is located above the outdoor unit.). Elevation Difference - Outdoor Below: Max. 50 ft. (This is the maximum elevation difference when the indoor unit is located above the outdoor unit.). Max. Temperature (Cooling) - Indoor Air Intake: 95°F DB/ 71°F WB. Max. Temperature (Cooling) - Outdoor Air Intake: 115°F DB. Min. Temperature (Cooling) - Indoor Air Intake: 67°F DB/ 57°F WB. Min. Temperature (Cooling) - Outdoor Air Intake: 50°F DB. Max. Temperat...